- Title
- Hyperoxemia and excess oxygen use in early acute respiratory distress syndrome: insights from the LUNG SAFE study
- Creator
- Madotto, Fabiana; Rezoagli, Emanuele; Brochard, Laurent; Laffey, John G.; Tai, Pham; Schmidt, Marcello; McNicholas, Bairbre; Protti, Alessandro; Panwar, Rakshit; Bellani, Giacomo; Fan, Eddy; van Haren, Frank
- Relation
- European Society of Intensive Care Medicine (ESICM), Brussels, Belgium
- Relation
- Critical Care Vol. 24, Issue 1, no. 125
- Publisher Link
- http://dx.doi.org/10.1186/s13054-020-2826-6
- Publisher
- BioMed Central Ltd
- Resource Type
- journal article
- Date
- 2020
- Description
- Background: Concerns exist regarding the prevalence and impact of unnecessary oxygen use in patients with acute respiratory distress syndrome (ARDS). We examined this issue in patients with ARDS enrolled in the Large observational study to UNderstand the Global impact of Severe Acute respiratory FailurE (LUNG SAFE) study. Methods: In this secondary analysis of the LUNG SAFE study, we wished to determine the prevalence and the outcomes associated with hyperoxemia on day 1, sustained hyperoxemia, and excessive oxygen use in patients with early ARDS. Patients who fulfilled criteria of ARDS on day 1 and day 2 of acute hypoxemic respiratory failure were categorized based on the presence of hyperoxemia (PaO2 > 100 mmHg) on day 1, sustained (i.e., present on day 1 and day 2) hyperoxemia, or excessive oxygen use (FIO2 ≥ 0.60 during hyperoxemia). Results: Of 2005 patients that met the inclusion criteria, 131 (6.5%) were hypoxemic (PaO2 < 55 mmHg), 607 (30%) had hyperoxemia on day 1, and 250 (12%) had sustained hyperoxemia. Excess FIO2 use occurred in 400 (66%) out of 607 patients with hyperoxemia. Excess FIO2 use decreased from day 1 to day 2 of ARDS, with most hyperoxemic patients on day 2 receiving relatively low FIO2. Multivariate analyses found no independent relationship between day 1 hyperoxemia, sustained hyperoxemia, or excess FIO2 use and adverse clinical outcomes. Mortality was 42% in patients with excess FIO2 use, compared to 39% in a propensity-matched sample of normoxemic (PaO2 55–100 mmHg) patients (P = 0.47). Conclusions; Hyperoxemia and excess oxygen use are both prevalent in early ARDS but are most often non-sustained. No relationship was found between hyperoxemia or excessive oxygen use and patient outcome in this cohort.
- Subject
- hyperoxia; hypoxia; hyperoxemia; hypoxemia; oxygen therapy; acute respiratory distress syndrome
- Identifier
- http://hdl.handle.net/1959.13/1441868
- Identifier
- uon:41557
- Identifier
- ISSN:1466-609X
- Language
- eng
- Reviewed
- Hits: 5584
- Visitors: 5575
- Downloads: 0